Hertel exophthalmometer base measurement

WitrynaThe measurement for the patient’s right eye should be determined with the examiner’s left eye and vice versa. In general, measurements between the two eyes should be equal. If the measurements are different by 2 or more millimeters, the patient should undergo additional evaluation. There are several types of exophthalmometers: Hertel and Luedde exophthalmometers measure the distance of the corneal apex from the level of the lateral orbital rim, while Naugle exophthalmometers measure the relative difference between each eye. • Hertel exophthalmometers take a measurement from the lateral orbital rim to the corneal apex. If a patient presents with an orbital fracture or after lateral orbitotomy, the use of a Hertel exophth…

Errors of Single-Mirror or Prism Hertel ... - ResearchGate

Witryna20 maj 2005 · For the normal subjects, the mean values of exophthalmos, asymmetry on protrusion, and base were 13.97, 0.54, and 106.45 mm, respectively in male subjects and 13.86, 0.56, and 105.31 mm,... Witryna3 wrz 2024 · The intra-observer correlation coefficients of the 3D reconstruction software, CT, and Hertel exophthalmometer measurements were 0.997, 0.942, and 0.953, … insufficient credit experience https://billfrenette.com

Clinical exophthalmometry: a comparative study of the Luedde …

WitrynaExophthalmometry is reliable and absolute measurement of proptosis is feasible. International standardization of Hertel exophthalmometry is required in order to … WitrynaExophthalmometry is a measurement of the anterior-posterior position of the globe, generally from the lateral orbital rim to the anterior corneal surface (Hertel exophthalmometry, Fig 2-2A). The Naugle exophthalmometer uses the frontal and maxillary bones as its reference structures (Fig 2-2B); this exophthalmometer is … Witryna8 lip 2009 · METHODS To test the reliability of our Hertel exophthalmometer, we determined the interobserver variation between two observers by measuring 160 eyes in healthy, adult, Caucasian, Dutch females and males (10 females and 10 males in each decade between 20 and 60 years of age). job interview cover letter sample

Reliability of Hertel Exophthalmometer Measurements - ICHGCP

Category:Reliability of Hertel Exophthalmometer Measurements

Tags:Hertel exophthalmometer base measurement

Hertel exophthalmometer base measurement

Exophthalmometer - an overview ScienceDirect Topics

Witryna19 gru 2016 · The Hertel exophthalmometer is used to determine the axial position of the eyes. The instrument is placed on the lateral orbital rim of each side, using as … Witryna24 wrz 2012 · The base measurement is determined by the bony orbital structures and should not be significantly affected over time by the soft tissue remodeling …

Hertel exophthalmometer base measurement

Did you know?

WitrynaA Hertel exophthalmometer measures the amount of anterior protrusion of the globes (Fig. 1-20). The examiner faces the patient, palpates the patient's lateral orbital rims, … Witryna11 sty 2024 · METHODS: The investigators developed an accurate and easy to use method for measuring abnormal eyeball protrusion using the TrueDepth camera of the iPhone 11 in comparison with a high-resolution 3D scanner as a reference to compare with the Hertel Exophthalmometer. OUTCOMES:

Witryna23 lut 2015 · For the entire study population, the Hertel EVs ranged from 10 mm to 22 mm; the mean EVs for the left eye (OS) and right eye (OD) were 15.0 ± 1.9 mm and … Witryna13 lip 2024 · Mean values for the base of the measurement (distance between the orbital rims) were 97.9 (SD ± 4.0) mm in CT and 113.7 (SD ± 4.9) mm in Hertel …

WitrynaProduct Description This instrument is used for precise exophthalmos measurements (e.g. exophthalmic goiter). The basis of the measurement for exophthalmos determination using the Hertel version is the outer orbital rim … Witryna12 sty 2024 · The Hertel exophthalmometer is used to determine the axial position of the eyes. The instrument is placed on the lateral orbital rim of each side, using as …

WitrynaThe purpose of this study was to compare the clinical usefulness of the newly developed Naugle superior and inferior orbital rim-based exophthalmometer with that of the …

WitrynaThe .gov means it’s official. Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site. insufficient credit file meaningWitryna1 paź 1984 · We used the Hertel exophthalmometer to measure the degree of protrusion in 681 adults, ranging in age from 18 to 91 years. ... The distance between lateral orbital rims (the base measure ment) was recorded to the nearest 1.0 mm. Height and weight were record ed for 290 subjects. We analyzed the data with the onetailed … job interview clothing womenWitrynaThe Hertel Exophthalmometer is used for precise measurement of the degree of forward displacement of the eye in the saggital axis (proptosis). The distance between the lateral orbital rim and the apex of the cornea serves as the dimension of the measurement; Dimensions 26(H) x 260(W) x 78(D) mm; Weight: 111g; Scale on … insufficient credit fileWitryna1 paź 1999 · Hertel exophthalmometry was used to assess ocular protrusion. The basis of exophthalmometry is the measure of the distance of the corneal apex from the level of the lateral orbital rim using an... job interview cover letterWitryna17 lip 2015 · The value of parameters in Hertel’s exophthalmometry was measured by using orbit computerized tomography (CT) in this study and it is suggested that the value of the D/C ratio could be used as the index of protrusion. 66 View 2 excerpts, references methods and background Interinstrument Variability in Hertel-Type Exophthalmometers job interview educationWitrynaThe Hertel exophthalmometer is used to determine the axial position of the eyes. The instrument is placed on the lateral orbital rim of each side, using as small of a base as possible. Depending on the device, lines … job interview dress code femaleWitryna12 wrz 2013 · Hertel exophthalmometer measurements are reliable for normal patients, but can be problematic when used on patients having orbital rim fractures because the device bases its measurements … insufficient credit history mean